Bonded Ferrite Magnetizer Machine
Main technical parameters
| Input voltage | 110V, 60hz | 
| Output voltage | 0 - 3000V | 
| Max. pulse current | 7000A | 
| Magnetizes the cycle | 2 - 5 s | 
| Electric capacity | Use 4*25μF capacitor; with different output capacities of 25, 50, 75 and 100μF. | 
| Energy | 360J | 
| Electric circuit control | 3 SCR(Silicon control trigger circuit) | 
Features
1. Output current measurement, directly output to BNC connector, provides plug-in fast output cable, detect current measurement coil.
2. The current output monitor has 2 BNC interfaces, 1 with peak hold reset circuit, and 1 direct output.
3. 3 SCRs have 3 trigger inputs. 3 sets of output leads.
4. The output voltage is dynamically monitored and controlled in real-time. The required output voltage value can be set through the potentiometer on the machine operation panel, with a setting accuracy of +/-1V. The magnetizing voltage is automatically compared with the set value and fed back to perform closed-loop control.
5. The door has a safety interlock design. When the door is open, the power can be cut off or the power can be turned on.
Pictures

The front panel of DXMM30C10 magnetizer machine

The upper part of the front panel

The lower part of the front panel

Interior circuit of DXMM30C10 magnetizer machine

The back panel of DXMM30C10 magnetizer machine

The lower part of the back panel
 
         
                